SP Data Points

Parameter Name

Data Point

ACL

Data Type

Min Value

Max Value

Liegenschaft

SP,NR=3

r-

INT

0

2147483647

WP_System

SP,NR=4

r-

INT

1

2

WW Type

SP,NR=5

r-

INT

0

4

FWS Type

SP,NR=6

r-

BOOL

0

1

Puffer Type

SP,NR=7

r-

BOOL

0

1

Softwareversion

SP,NR=9

r-

INT

0

0

Verdichter_Status

SP,NR=10

r-

INT

0

11

Verdichter laeuft seit

SP,NR=11

r-

INT

10

100000

Verdichter Einschaltverz.(sec)

SP,NR=12

r-

INT

0

10800

Betriebsart [1]

SP,NR=13

r-

INT

0

7

HKR Soll_Raum

SP,NR=69

r-

FLOAT

10.0

25.0

HKR Aufheiztemp. (K)

SP,NR=71

r-

INT

1

10

HKR Absenktemp. (K)

SP,NR=72

r-

INT

-10

-1

HKR Heizgrenze

SP,NR=76

r-

INT

0

45

HKR RLT Soll_oHG (Heizkurve)

SP,NR=80

r-

FLOAT

15.0

40.0

HKR RLT Soll_0 (Heizkurve)

SP,NR=81

r-

FLOAT

20.0

50.0

HKR RLT Soll_uHG (Heizkurve)

SP,NR=82

r-

FLOAT

25.0

60.0

WW Normaltemp.

SP,NR=83

r-

INT

10

75

WW Hysterese Normaltemp.

SP,NR=84

r-

INT

1

10

WW Minimaltemp.

SP,NR=85

r-

INT

5

45

WW Hysterese Minimaltemp.

SP,NR=86

r-

INT

1

10

BSZ HKP Betriebsstunden

SP,NR=153

r-

INT

0

100000

BSZ HKP Schaltung

SP,NR=155

r-

INT

0

100000

BSZ EQ Betriebsstunden

SP,NR=162

r-

INT

0

100000

BSZ EQ Schaltungen

SP,NR=164

r-

INT

0

100000

BSZ WWV Betriebsstunden

SP,NR=165

r-

INT

0

100000

BSZ WWV Schaltungen

SP,NR=167

r-

INT

0

100000

BSZ ZIPWW Betriebsstunden

SP,NR=168

r-

INT

0

100000

BSZ ZIPWW Schaltungen

SP,NR=170

r-

INT

0

100000

BSZ Verdichter Betriebsst. WW

SP,NR=171

r-

INT

0

100000

BSZ Verdichter Betriebsst. HKR

SP,NR=172

r-

INT

0

100000

BSZ Verdichter Betriebsst. ges

SP,NR=173

r-

INT

0

100000

BSZ Verdichter akt. Laufzeit

SP,NR=174

r-

INT

0

100000

MKR2 Aktiviert

SP,NR=222

r-

INT

0

2

Energiezaehler

SP,NR=263

r-

INT

0

2

BSZ Verdichter Schaltung WW

SP,NR=375

r-

INT

0

100000

MP Data Points

Parameter Name

Data Point

ACL

Data Type

Min Value

Max Value

Temp. Aussen

MP,NR=0

r-

FLOAT

-20.0

40.0

Temp. Aussen verzoegert

MP,NR=1

r-

FLOAT

-20.0

40.0

Temp. Brauchwasser

MP,NR=2

r-

FLOAT

0.0

70.0

Temp. Vorlauf

MP,NR=3

r-

FLOAT

0.0

70.0

Temp. Ruecklauf

MP,NR=4

r-

FLOAT

0.0

70.0

Temp. Pufferspeicher

MP,NR=5

r-

FLOAT

0.0

70.0

Temp. EQ_Eintritt

MP,NR=6

r-

FLOAT

-20.0

30.0

Temp. EQ_Austritt

MP,NR=7

r-

FLOAT

-20.0

30.0

Temp. Sauggas

MP,NR=9

r-

FLOAT

-20.0

30.0

Temp. Frischwasser_Istwert

MP,NR=11

r-

FLOAT

0.0

70.0

Temp. Verdampfung

MP,NR=12

r-

FLOAT

-50.0

30.0

Temp. Kondensation

MP,NR=13

r-

FLOAT

-50.0

60.0

Temp. Heissgas

MP,NR=15

r-

FLOAT

0.0

150.0

Niederdruck (bar)

MP,NR=20

r-

FLOAT

0.0

18.0

Hochdruck (bar)

MP,NR=21

r-

FLOAT

0.0

40.0

Heizkreispumpe

MP,NR=22

r-

BOOL

False

True

EQ Pumpe (Ventilator)

MP,NR=24

r-

BOOL

False

True

Warmwasservorrang

MP,NR=25

r-

BOOL

False

True

Zirkulationspumpe WW

MP,NR=29

r-

BOOL

False

True

Verdichter

MP,NR=30

r-

BOOL

False

True

Stoerung

MP,NR=31

r-

BOOL

False

True

Hauptschalter

MP,NR=36

r-

BOOL

False

True

FWS Stroemungsschalter

MP,NR=38

r-

BOOL

False

True

BSZ Verdichter Schaltungen

MP,NR=41

r-

INT

0

100000

Frischwasserpumpe

MP,NR=50

r-

INT

0

100

Verdichteranforderung

MP,NR=56

r-

INT

0

5

HKR_Sollwert

MP,NR=57

r-

FLOAT

0.0

50.0